There is much confusion in the marketplace about the different types of UPS systems and their characteristics. Each of these UPS types is defined, practical applications of each are discussed, and advantages and disadvantages are listed. With this information, an educated decision can be made as to the appropriate UPS topology for a given need.

The varied types of UPSs and their attributes often cause confusion in the data center industry. For example, it is widely believed that there are only two types of UPS systems, namely standby UPS and online UPS. These two commonly used terms do not correctly describe many of the UPS systems available.

Many misunderstandings about UPS systems are cleared up when the different types of UPS topologies are properly identified. Common design approaches are reviewed here, including brief explanations about how each topology works. This will help you to properly identify and compare systems.

CTVS07RF-21-75AA_Datasheet PDF

Partnered Content: NGK contributing to the speard of IoT devices through new ceramic Li-ion rechargeable batteries  

UPS types A variety of design approaches are used to implement UPS systems, each with distinct performance characteristics. The most common design approaches are as follows: * Standby * Line Interactive * Standby on-line hybrid * Standby-Ferro * Double Conversion On-Line * Delta Conversion On-Line

CTVS07RF-21-75AA_Datasheet PDF

The Standby UPS The Standby UPS is the most common type used for Personal Computers. In the block diagram illustrated in Figure 1, the transfer switch is set to choose the filtered AC input as the primary power source (solid line path), and switches to the battery / inverter as the backup source should the primary source fail. When that happens, the transfer switch must operate to switch the load over to the battery / inverter backup power source (dashed path). The inverter only starts when the power fails, hence the name Standby.”

If you ignore the optical space, I don't see anything on the horizon that's a serious competitor to the hard-disk drive,” added Kryder.

The power requirement required by data centers and network rooms varies on a minute by minute basis depending on the computational load. This magnitude of this variation has grown and continues to grow dramatically with the deployment of power management technologies in servers and communication equipment. This variation gives rise to new problems relating to availability and management.

Data centers and network rooms draw a total electrical power, which is the sum of the installed Information Technology. Historically, this equipment consumed power at a value that varied only slightly depending on the computational load or the mode of operation. The laptop computer created the requirement that processor power be managed to conserve battery life. Power Management technology allowed the power of laptop computer processors to be reduced up to 90% when lightly loaded. This technology has matured and has recently been incorporated into server design. The result is that newly developed servers can have a power consumption that varies dramatically with time.

When power varies with time, a variety of new problems occur for the design and management of datacenters and network rooms. A few years ago, this problem was negligible. The problem is now reached the point where it is significant, and the magnitude of the problem is growing.

Changes in power consumption can lead to unplanned and undesirable consequences in the data center and network room environment; including tripped circuit breakers, overheating, and loss of redundancy in redundant power systems. This situation creates new challenges for people designing or operating data centers and network rooms.